| Customization: | Available |
|---|---|
| Type: | Sensor |
| Certification: | CE |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency


Indicator light | Function Definition |
CHANNEL1-4 | Vibration 1 - 4 channel raw signal |
MODULEOK | Indicates that the monitor is working properly |
FAULT | A protection fault indicates that a problem is preventing the system from functioning properly |
USER INHIBIT | Indicates that the relay is intentionally set to disable operation |
RX/TX | Indicates Ethernet status and monitor communication with remote software |
RELAY | Indicates whether the relay is operating |
BYPASS | bypass |
RPM | Speed channel original signal |
Instrument power supply | 16VDC~30VDC, power consumption ≤6W or 95VAC~285VAC, rated power 15W |
Sensor power supply | -24VDC, +24VDC, constant current source 4mA |
Signal input | vibration sensor signals such as acceleration (ICP) , speed, eddy current, etc. |
1- channel speed sensor can be connected to Hall-type speed sensor, magnetoelectric speed sensor, eddy current sensor signal | |
Frequency response | Can be configured through software |
Signal Conditioning | Resolution: displacement 1μm, speed 0.01mm/s; display accuracy: 0.5%; measurement accuracy: ±0.1RPM, vibration 0.5%; |
filter | Digital filtering |
Display Mode | LCD |
Current output | 4-20mADC output, proportional to vibration range |
Output load | Maximum 500Ω |
Output accuracy | 0.5% |
Buffered output | 4 vibrations + 1 speed |
Output impedance | 100Ω (maximum 5mA) Maximum transmission distance 300m |
Relay output | 6 sets of programmable relays (SPDT) |
Relay contact capacity 220VAC / 5A , 125VDC / 2A | |
Communication interface | Ethernet and 485 |
Electromagnetic compatibility | CE certification |
Operating temperature | -35℃ - +70℃ |
Storage temperature | -40℃ - +100℃ |
Relative humidity | 95 % non-condensing |
Material | All-aluminum chassis |
External (installation) dimensions | See picture |
weight | Less than 1.4 Kg |
Installation | 35mm DIN rail mounting or panel mounting |
External (installation) dimensions | See picture |
weight | Less than 1.4 kg |
Installation | 35mm DIN rail mounting or panel mounting |
RESET | Reset button |
INFO/CONTRST Embedded key function | 1: Display user account/password, IP address, firmware/hardware version number: Click 2 : LCD brightness adjustment: long press 2 - 3 on the display interfaceS regulation 3 : Reset default settings: User account name, password, network status, long press 5S |
Sensor Type | Set the vibration sensor type acceleration (ICP), speed, eddy current and other vibration sensor signals Set the speed Hall speed sensor, magnetoelectric speed sensor, eddy current sensor signal |
Sensitivity | Setting Sensitivity |
Measurement unit settings | μm pp/μm PK/ mils PP/Mils PK- PK |
Range setting | Set the upper and lower limits |
Relay related settings | Related/Not Related |
Alarm/danger value settings | Set alarm danger value |
Alarm mode setting | Manual/Automatic |
4-20mA calibration | Calibrate 4-20mA output |
IP Settings | Setting IP |