The magnetoelectric velocity vibration sensor is an inertial sensor used to measure the vibration (absolute vibration relative to free space) of bearing housings, machine casings, or structures. Its output voltage is proportional to the vibration velocity. The sensor operates without an external power supply, features a two-wire structure, and can handle both medium and low-frequency vibration measurements. It is suitable for long- term online monitoring or periodic measurements. The velocity can also be easily integrated into displacement by the instrument. This measurement allows for the comprehensive evaluation of the operating conditions of rotating or reciprocating machinery. It is directly mounted on the machine casing, making it very convenient to use and maintain.
The TM36X magnetoelectric velocity vibration sensor conforms to the API 670 standard.
TM36X: Features explosion-proof design. Can directly replace Bentley 9200/74712/4760F and Shin- Chuan CV851 speed sensors.
TM36X: Optional sensitivity to meet user customization requirements, including versions for medium and high temperature applications.
Electrical Characteristics :
TM361 Sensitivity: 20mV/mm/s, peak ±5% (measured at 80Hz, speed 10mm/s)
TM36X Sensitivity: Customized
TM36F Sensitivity: 28.5mV/mm/s, peak ±3% (measured at 80Hz, speed 10mm/s)
Frequency Response: 4.5/10ÿ1000Hz (3dB) Amplitude Linearity: <3% Lateral Sensitivity: <5%
MaximumMeasurable Displacement: 2000um (peak-to-peak)
Shock Resistance: Withstands acceleration up to 50g peak value Output Resistance: ÿ600ÿ
Insulation Resistance: >20Mÿ Grounding:
Floating ground output Electromagnetic Compatibility: CE compliant Cable Outlet:
Top connector and side cable lead length: Maximum 300m between sensor and monitor; frequency attenuation occurs with increasing length.
Explosion-proof Performance : Explosion-proof Rating: Ex d IIC T6 Gb/Ex tD A21 When used in hazardous areas (explosion-proof requirements) with an IP65 rating and a temperature of 80ÿ, an intrinsically safe barrier should be installed.
Environmental restrictions for operating and storage temperature: -40ÿ to +125ÿ
Relative humidity: 95% non-condensing when using connector exit method; 100% non-immersion in water when using integral cable exit method.
Environmental protection: The connector-outlet type has an IP65 protection rating; the direct-outlet cable type has an IP67 protection rating. Cable ends (terminals) must not be immersed in water.
Mechanical properties :
Housing material: 316L;
Volume: See Figures 1, 2, and 3 on page 5;
Weight: 300g